IDP Ion Desorption Probe.

The Hiden IDP is a quadrupole ion desorption probe for direct analysis of low-energy ions, neutrals and radicals generated in UHV surface science experiments.

5,000 amu
Maximum mass range
100 ns
Signal gating resolution
7 decades
Pulse ion counting display range
IDP ion desorption probe with cryo shroud
IDP Ion Desorption Probe · Residual gas analysis

Overview.

The Hiden IDP is a quadrupole ion desorption probe for direct analysis of low-energy ions, neutrals and radicals generated in UHV surface science experiments. It supports electron-stimulated, photon-stimulated, and thermal desorption studies with positive- and negative-ion detection.

Direct low-energy ion analysis for stimulated desorption research

Four-lens ion optics with an integral electron ionizer collect externally generated species for mass and yield measurements. A pole bias mid-axis potential allows external ions to be measured, while pulse ion counting provides a continuous seven-decade display. Triple-filter quadrupole options and mass ranges to 5,000 amu extend sensitivity and high mass capability.

Signal gating to 100 ns supports mass distributions against time, including time-of-flight studies, and sample temperature can be displayed alongside thermal desorption data. This combination is designed for direct stimulated desorption measurements and low-energy ion analysis in UHV surface science experiments.

Typical applications

Surface scienceCatalysis

Key Features.

  • Pulse ion counting provides continuous seven-decade data presentation, supporting measurements across a wide signal range
  • Direct observation of positive and negative ions, radicals and neutrals reveals species generated in UHV surface experiments
  • Four-lens ion optics with an integral electron ionizer improve collection of externally generated low-energy ions
  • A pole bias mid-axis potential allows external ions to be measured directly
  • A high-sensitivity triple-filter quadrupole with mass range options to 5,000 amu extends analysis to higher mass species
  • Signal gating with 100 ns resolution supports time-resolved mass distribution studies

Software.

Every system ships with control software. Which package suits depends on whether you are running quantitative gas analysis, evolved gas work, or building your own acquisition routines.

Related instruments.

  • EPIC Research-Grade UHV and XHV Mass Spectrometer

    The Hiden EPIC and EPIC 1000 Series extend high-performance residual gas analysis to neutrals, radicals and positive or negative ions.

  • 3F Series Triple-Filter Quadrupole Mass Spectrometers

    The Hiden 3F and 1000 Series are high-precision triple-filter quadrupole mass spectrometers for analytical residual gas and process applications.

  • EQS

    A system for the analysis of secondary positive and negative ions from solid samples

Talk to an applications engineer.

Describe the experiment. An applications engineer reads it personally and typically replies within one business day.

Or call 1-888-96-HIDEN, Monday to Friday, 8:30am to 5pm ET.